Desuperheaters
Probe-Type/Integral Control
The combination of desuperheater
spray element and spraywater control provides extremely high
turndown capability, double that of previously available units.
Multiple nozzles are staged to achieve
variable sprayhead Cv's, as illustrated below in photographs of
15%, 50% and 100% spraypatterns.
15%
50%
100%
Inserted into steam flow via a
3 inch flanged connection into the steam piping. Spraywater is
connected directly to the desuperheater via 1 inch flanged
connection.
Water
pressure of 50 to 1600 psi above steam pressure is is
employed to generate thin film, conical sprays which are
injected into the
A separate water control
valve is not required because water flow control is an
integral function of the desuperheater itself.
High Temperature Remote Control
Element
Yarway has developed a
revolutionary design to address the need for desuperheaters that can
operate reliably in steam flows over
1100° Fahrenheit. By locating the control elements above the
"probe" portion of the
desuperheater, the sliding element is not exposed to the
direct flow of steam.
Small Pipe In-Line
(SPID®)
A
fixed orifice design that is installed between ANSI standard
flanges. Spraywater control is by an external control valve. |